safetyPLC
safetyPLC
less than a minute
The Safety PLC provides information about the state of the Safety PLC and which safety project is applied.
- The
Run Lamp
is green if the Safety PLC receives a run command, else LED is switched off. - The
Acknowledge
button is linked to the iErrorAcknowledge. Pressing theAcknowledge
button resets theINTERLOCK FUNCTIONS
. So that the warnings and error are reset. - The
Project CRC
is a hex number representation of the safety project applied to the safety PLC. - The
Serial Number
is the Safety PLC serial number. - The
Logic State
defines the state of the Safety PLC. The states are:OFFLINE
,RUN
,SAFE
,START
,PREPARE
,RESTORE
orPROJECT-CRC-OK
. - The Safety PLC
SDOs
can be read out after pressing theRead SDOs
button. This wil request the core temperature and voltage.
The FSoE Communication provides information about the connected slaves.
- Cmd to/from slave states are:
FailSafeData
,Reset
,ProcessData
,Connection
orParameter
. - The connection ID provides information about the slave ID.